NX-series System Unit User’s Manual (W523) Introduction Thank you for purchasing a NX-series System Unit. This manual contains information that is necessary to use the NX-series System Unit. Please read this manual and make sure you understand the functionalit y and performance of the NX-series System Unit. NX-series Communications Interface Units User's Man-ual Learning how to use NX-series Communications Inter-face Units NX-series Safety Control Unit User's Manual Learning how to use NX-series Safety Control Units NX-series Load Cell Input Unit User's Manual Learning how to use an NX-series Load Cell Input Unit NX-series IO-Link Master Unit User. Relevant Manuals 4 NX-series Data Reference Manual (W525) Relevant Manuals To use the NX-series, you must refer to the manuals for all related products. Read all of the manuals that are relevant to your system configuration and application before you use the NX-series. Konica minolta bizhub c451 user manual. Most operations are performed from the Sysmac Studio Automation Software.
Provides simplicity and flexibility in connecting serial devices to EtherCAT
about this Product Family
Related Contents
Nx-series Communications Interface Units User's Manual Pdf
last update: August 1, 2018
General Specification
* Refer to the OMRON website (http://www.ia.omron.com/) or consult your OMRON representative for the most recent applicable standards for each model.
Specifications of Individual UnitsNX-CIF101
*1. Setting is possible in the Unit operation settings of the Sysmac Studio.
*2. This is the value of the RS signal when the port enters the Operational state or immediately after the port is restarted. The initial value is disabled when RS/CS flow control is set. *3. This setting is provided for communications protocols that assume the end of the data if data is not received for a specific period of time. For example, if the number of characters to determine the end is set to 35, the end of the data will be assumed if data is not received for the time required to receive 3.5 characters. *4. If the baud rate is set to higher than 19,200 bps, refer to the manual for the remote communications device. *5. The settings that are backed up are saved in memory in the Communications Coupler Unit. The settings that are backed up are not saved in the Communications Interface Units. NX-CIF105
*1. Setting is possible in the Unit operation settings of the Sysmac Studio.
*2. This is the value of the RS signal when the port enters the Operational state or immediately after the port is restarted. The initial value is disabled when RS/CS flow control is set. It is also disabled for the NX-CIF105. *3. This setting is provided for communications protocols that assume the end of the data if data is not received for a specific period of time. For example, if the number of characters to determine the end is set to 35, the end of the data will be assumed if data is not received for the time required to receive 3.5 characters. *4. The maximum total cable length for multidrop connections is 1,200 m. *5. The settings that are backed up are saved in memory in the Communications Coupler Unit. The settings that are backed up are not saved in the Communications Interface Units. NX-CIF210
*1. Setting is possible in the Unit operation settings of the Sysmac Studio.
*2. This is the value of the RS signal when the port enters the Operational state or immediately after the port is restarted. The initial value is disabled when RS/CS flow control is set. *3. This setting is provided for communications protocols that assume the end of the data if data is not received for a specific period of time. For example, if the number of characters to determine the end is set to 35, the end of the data will be assumed if data is not received for the time required to receive 3.5 characters. *4. If the baud rate is set to higher than 19,200 bps, refer to the manual for the remote communications device. *5. The settings that are backed up are saved in memory in the Communications Coupler Unit. The settings that are backed up are not saved in the Communications Interface Units. Version InformationConnecting with CPU Units
Refer to the user's manual for the CPU Unit for the CPU Unit to which NX Units can be connected.
Nx-series Communications Interface Units User's Manual 2016
Note: Some Units do not have all of the versions given in the table. If a Unit does not have the specified version, support is
provided by the oldest available version after the specified version. Refer to the user's manuals for the specific Units for the relation between models and versions. Connecting with an EtherCAT Coupler Unit
Note: Some Units do not have all of the versions given in the above table. If a Unit does not have the specified version,
support is provided by the oldest available version after the specified version. Refer to the user's manuals for the specific Units for the relation between models and versions. * The serial communications instructions for the CIF Units are supported by CPU Units with unit version 1.11 or later. If it is not used, it is available for a CPU Unit with unit version 1.10. Refer to the Instructions Reference Manual for the CPU Unit or Industrial PC for the serial communications instructions for the CIF Units. Connecting with an EtherNet/IP Coupler Unit
Note: Some Units do not have all of the versions given in the above table. If a Unit does not have the specified version,
support is provided by the oldest available version after the specified version. Refer to the user's manuals for the specific Units for the relation between models and versions. *1 Refer to the user’s manual for the EtherNet/IP Coupler Units for information on the unit versions of EtherNet/IP Units that are compatible with EtherNet/IP Coupler Units. *2 Refer to the user’s manual for the EtherNet/IP Coupler Units for information on the unit versions of CPU Units and EtherNet/IP Units that are compatible with EtherNet/IP Coupler Units. *3 Serial communications instructions for CIF Units cannot be used if they are connected to an EtherNet/IP Coupler Unit. *4 For connection to an EtherNet/IP Coupler Unit with unit version 1.0, You can connect only to the peripheral USB port on the EtherNet/IP Coupler Unit. You cannot connect with any other path. If you need to connect by another path, use an EtherNet/IP Coupler Unit with unit version 1.2 or later.
last update: August 1, 2018
Product CategoryNx-series Communications Interface Units User's Manual 2017
© Copyright OMRON Corporation 2007 - 2019. All Rights Reserved.
Provides simplicity and flexibility in connecting serial devices to EtherCATNx-series Communications Interface Units User's Manual Free
about this Product Family
Related Contents
2001 qx4 repair manual free download. last update: October 11, 2016
• Just 12 mm wide, saving space in your cabinet.
• Three models are available with a choice of one RS-422A/485, one RS-232C, or two RS-232C ports.
• Screwless push-in terminal block (1-port model) and D-Sub connector (2-port model) significantly reduce wiring work.
• No-protocol communications are supported as the communications protocol.
• The maximum baud rate is 230.4 kbps. Samsung galaxy s4 mini user guide pdf. The baud rate can be selected to match the connected serial devices.
• The settings are backed up and saved in the EtherCAT Coupler Unit. This facilitates commissioning and maintenance.
• The serial line monitor enables you to check the communications status with serial devices on the Sysmac Studio for easy and reliable startup of the devices.
Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products.
EtherCAT® is a registered trademark of Beckhoff Automation GmbH for their patented technology. EtherNet/IPTM is the trademarks of ODVA. Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.
last update: October 11, 2016
Product Category
© Copyright OMRON Corporation 2007 - 2019. All Rights Reserved.
Comments are closed.
|
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |